The 655 kVA Cummins Diesel Generator Set is powered by a high-performance Cummins diesel engine and equipped with a high-quality alternator and intelligent control system. It offers excellent power performance, stable operation, good fuel efficiency, long service life, and easy maintenance.
the generator set is suitable for a wide range of applications, including factories, commercial buildings, hotels, hospitals, warehouses, data centers, construction sites, and other facilities requiring a reliable backup power supply.
| Type | Output Power | Current | Engine model | Cylinder | Bore*Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight(kg) | |
| KW | KVA | (A) | (mm) | (L) | g/kw.h | L*W*H | ||||
| Dongfeng Cummins series. | ||||||||||
| JTC-15GF | 15 | 18.75 | 27 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| JTC-20GF | 20 | 25 | 36 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| JTC-24GF | 24 | 30 | 43.2 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 710 |
| JTC-30GF | 30 | 37.5 | 54 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 800 |
| JTC-40GF | 40 | 50 | 72 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 920 |
| JTC-50GF | 50 | 62.5 | 90 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 950 |
| JTC-64GF | 64 | 80 | 115.2 | 4BTA3.9-G11 | 4 | 102*120 | 3.9 | 210 | 1850*800*1300 | 1000 |
| JTC-80GF | 80 | 100 | 144 | 6BT5.9-G2 | 6 | 102*120 | 5.9 | 210 | 2250*800*1300 | 1250 |
| JTC-100GF | 100 | 125 | 180 | 6BTA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*800*1300 | 1300 |
| JTC-120GF | 120 | 150 | 216 | 6BTAA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*830*1300 | 1350 |
| JTC-150GF | 150 | 187.5 | 270 | 6CTA8.3-G2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1600 |
| JTC-180GF | 180 | 225 | 324 | 6CTAA8.3-G2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1700 |
| JTC-200GF | 200 | 250 | 360 | 6LTAA8.9-G2 | 6 | 114*145 | 8.9 | 207 | 2600*970*1500 | 2000 |
| JTC-220GF | 220 | 275 | 396 | 6LTAA8.9-G3 | 6 | 114*145 | 8.9 | 203 | 2600*970*1500 | 2000 |
| JTC-320GF | 320 | 400 | 576 | 6ZTAA13-G3 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| JTC-400GF | 400 | 500 | 720 | 6ZTAA13-G4 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| JTC-400GF | 400 | 500 | 720 | QSZ13-G2 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| JTC-450GF | 450 | 562.5 | 810 | QSZ13-G3 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| Chongqing Cummins series. | ||||||||||
| JTC-200GF | 200 | 250 | 360 | NT855-GA | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2600 |
| JTC-200GF | 200 | 250 | 360 | MTA11-G2 | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2700 |
| JTC-250GF | 250 | 312.5 | 450 | NTA855-G1A | 6 | 140*152 | 14 | 207 | 3100*1050*1750 | 2900 |
| JTC-280GF | 280 | 350 | 504 | MTAA11-G3 | 6 | 125*147 | 11 | 210 | 3100*1050*1750 | 2900 |
| JTC-280GF | 280 | 350 | 504 | NTA855-G1B | 6 | 140*152 | 14 | 206 | 3100*1050*1750 | 2950 |
| JTC-300GF | 300 | 375 | 540 | NTA855-G2A | 6 | 140*152 | 14 | 206 | 3200*1050*1750 | 3000 |
| JTC-350GF | 350 | 437.5 | 630 | NTAA855-G7A | 6 | 140*152 | 14 | 205 | 3300*1250*1850 | 3200 |
| JTC-400GF | 400 | 500 | 720 | KTA19-G3A | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3700 |
| JTC-450GF | 450 | 562.5 | 810 | KTA19-G4 | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3900 |
| JTC-500GF | 500 | 625 | 900 | KTA19-G8 | 6 | 159*159 | 19 | 206 | 3500*1500*2000 | 4200 |
| JTC-550GF | 550 | 687.5 | 990 | KTAA19-G6A | 6 | 159*159 | 19 | 206 | 3600*1500*2000 | 4800 |
| JTC-600GF | 600 | 750 | 1080 | KT38-GA | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7000 |
| JTC-650GF | 650 | 812.5 | 1170 | KTA38-G2 | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7500 |
| JTC-700GF | 700 | 875 | 1260 | KTA38-G2B | 12 | 159*159 | 38 | 206 | 4400*1750*2350 | 8000 |
| JTC-800GF | 800 | 1000 | 1440 | KTA38-G2A | 12 | 159*159 | 38 | 206 | 4500*1750*2350 | 8200 |
| JTC-900GF | 900 | 1125 | 1620 | KTA38-G5 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 8800 |
| JTC-1000GF | 1000 | 1250 | 1800 | KTA38-G9 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 9200 |
| JTC-1100GF | 1100 | 1375 | 1980 | KTA50-G3 | 16 | 159*159 | 50 | 205 | 5300*2080*2500 | 10000 |
| JTC-1200GF | 1200 | 1500 | 2160 | KTA50-G8 | 16 | 159*159 | 50 | 205 | 5700*2280*2500 | 10500 |
| JTC-1440GF | 1440 | 1800 | 2592 | QSK50G7 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 12500 |
| JTC-1680GF | 1680 | 2100 | 3024 | QSK60G3 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 13000 |
| JTC-1760GF | 1760 | 2200 | 3168 | QSK60G4 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
| JTC-1840GF | 1840 | 2300 | 3312 | QSK60G13 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
Our Advantages
Strict Quality Control for Reliable Generator Sets
We adhere to high-standard manufacturing. High-quality components are adopted instead of inferior spare parts. Every production procedure, from sheet metal processing and wiring assembly to complete unit assembly, follows standardized technical requirements. Every detail is strictly checked to lower failure risks and ensure long-term stable operation under various harsh working conditions.


Complete Pre‑sales & After‑sales Service





FAQ
Q: What Type Of Application Is The 655kw Cummins Standby Generator Designed For?
A: The 655kw cummins standby generator is intended for applications that require electrical power within its rated capacity and duty. Depending on the configuration, it can support standby, prime, commercial, industrial, construction, or project-based power requirements.
Q: Which Load Information Should Be Checked Before Selecting A 655kw Cummins Standby Generator?
A: Review the continuous load, peak demand, motor starting current, power factor, voltage, frequency, phase, operating hours, and expected load growth. These details help determine the required generator rating and configuration.
Q: What Duty Rating Should I Specify For A 655kw Cummins Standby Generator?
A: The choice between standby, prime, or other duty ratings depends on how often the generator will operate and the expected load profile. Buyers should provide estimated running hours and typical loading so the appropriate engine and alternator rating can be selected.
Q: What Configuration Options Are Available For A 655kw Cummins Standby Generator?
A: Depending on the model, configuration can include voltage and frequency selection, control functions, fuel-tank arrangement, enclosure type, ATS integration, remote monitoring, and other project-specific requirements. Availability should be confirmed for the selected model.
Q: What Information Helps Suppliers Quote A 655kw Cummins Standby Generator Accurately?
A: Provide the required power, voltage, frequency, phase, application, duty rating, installation location, ambient conditions, enclosure preference, control requirements, and expected operating hours. For a 655KW unit, a load list is especially useful for confirming the specification.
Hot Tags: 655kw cummins standby generator, China 655kw cummins standby generator manufacturers, suppliers, factory