The Cummins 125kVA Diesel Generator Set is a high-performance power generation solution designed for industrial, commercial, and emergency backup power applications.
Powered by a reliable Cummins diesel engine and equipped with a high-quality alternator, this generator set delivers stable power output, excellent durability, fuel efficiency, and dependable operation. It is an ideal choice for factories, hotels, hospitals, office buildings, shopping centers, construction sites, and other facilities requiring an uninterrupted power supply.
With a rated capacity of 125kVA, equivalent to 100kW at a power factor of 0.8, the generator can provide reliable electricity for various electrical equipment, production machinery, lighting systems, air conditioning units, water pumps, and other essential loads.
| Type | Output Power | Current | Engine model | Cylinder | Bore*Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight(kg) | |
| KW | KVA | (A) | (mm) | (L) | g/kw.h | L*W*H | ||||
| Dongfeng Cummins series. | ||||||||||
| JTC-15GF | 15 | 18.75 | 27 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| JTC-20GF | 20 | 25 | 36 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| JTC-24GF | 24 | 30 | 43.2 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 710 |
| JTC-30GF | 30 | 37.5 | 54 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 800 |
| JTC-40GF | 40 | 50 | 72 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 920 |
| JTC-50GF | 50 | 62.5 | 90 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 950 |
| JTC-64GF | 64 | 80 | 115.2 | 4BTA3.9-G11 | 4 | 102*120 | 3.9 | 210 | 1850*800*1300 | 1000 |
| JTC-80GF | 80 | 100 | 144 | 6BT5.9-G2 | 6 | 102*120 | 5.9 | 210 | 2250*800*1300 | 1250 |
| JTC-100GF | 100 | 125 | 180 | 6BTA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*800*1300 | 1300 |
| JTC-120GF | 120 | 150 | 216 | 6BTAA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*830*1300 | 1350 |
| JTC-150GF | 150 | 187.5 | 270 | 6CTA8.3-G2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1600 |
| JTC-180GF | 180 | 225 | 324 | 6CTAA8.3-G2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1700 |
| JTC-200GF | 200 | 250 | 360 | 6LTAA8.9-G2 | 6 | 114*145 | 8.9 | 207 | 2600*970*1500 | 2000 |
| JTC-220GF | 220 | 275 | 396 | 6LTAA8.9-G3 | 6 | 114*145 | 8.9 | 203 | 2600*970*1500 | 2000 |
| JTC-320GF | 320 | 400 | 576 | 6ZTAA13-G3 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| JTC-400GF | 400 | 500 | 720 | 6ZTAA13-G4 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| JTC-400GF | 400 | 500 | 720 | QSZ13-G2 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| JTC-450GF | 450 | 562.5 | 810 | QSZ13-G3 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| Chongqing Cummins series. | ||||||||||
| JTC-200GF | 200 | 250 | 360 | NT855-GA | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2600 |
| JTC-200GF | 200 | 250 | 360 | MTA11-G2 | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2700 |
| JTC-250GF | 250 | 312.5 | 450 | NTA855-G1A | 6 | 140*152 | 14 | 207 | 3100*1050*1750 | 2900 |
| JTC-280GF | 280 | 350 | 504 | MTAA11-G3 | 6 | 125*147 | 11 | 210 | 3100*1050*1750 | 2900 |
| JTC-280GF | 280 | 350 | 504 | NTA855-G1B | 6 | 140*152 | 14 | 206 | 3100*1050*1750 | 2950 |
| JTC-300GF | 300 | 375 | 540 | NTA855-G2A | 6 | 140*152 | 14 | 206 | 3200*1050*1750 | 3000 |
| JTC-350GF | 350 | 437.5 | 630 | NTAA855-G7A | 6 | 140*152 | 14 | 205 | 3300*1250*1850 | 3200 |
| JTC-400GF | 400 | 500 | 720 | KTA19-G3A | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3700 |
| JTC-450GF | 450 | 562.5 | 810 | KTA19-G4 | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3900 |
| JTC-500GF | 500 | 625 | 900 | KTA19-G8 | 6 | 159*159 | 19 | 206 | 3500*1500*2000 | 4200 |
| JTC-550GF | 550 | 687.5 | 990 | KTAA19-G6A | 6 | 159*159 | 19 | 206 | 3600*1500*2000 | 4800 |
| JTC-600GF | 600 | 750 | 1080 | KT38-GA | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7000 |
| JTC-650GF | 650 | 812.5 | 1170 | KTA38-G2 | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7500 |
| JTC-700GF | 700 | 875 | 1260 | KTA38-G2B | 12 | 159*159 | 38 | 206 | 4400*1750*2350 | 8000 |
| JTC-800GF | 800 | 1000 | 1440 | KTA38-G2A | 12 | 159*159 | 38 | 206 | 4500*1750*2350 | 8200 |
| JTC-900GF | 900 | 1125 | 1620 | KTA38-G5 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 8800 |
| JTC-1000GF | 1000 | 1250 | 1800 | KTA38-G9 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 9200 |
| JTC-1100GF | 1100 | 1375 | 1980 | KTA50-G3 | 16 | 159*159 | 50 | 205 | 5300*2080*2500 | 10000 |
| JTC-1200GF | 1200 | 1500 | 2160 | KTA50-G8 | 16 | 159*159 | 50 | 205 | 5700*2280*2500 | 10500 |
| JTC-1440GF | 1440 | 1800 | 2592 | QSK50G7 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 12500 |
| JTC-1680GF | 1680 | 2100 | 3024 | QSK60G3 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 13000 |
| JTC-1760GF | 1760 | 2200 | 3168 | QSK60G4 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
| JTC-1840GF | 1840 | 2300 | 3312 | QSK60G13 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
Key Features
- Reliable Cummins Engine: Equipped with a high-performance Cummins diesel engine, offering dependable power and long service life.
- 125kVA Rated Capacity: Provides 100kW output at a power factor of 0.8, suitable for industrial and commercial applications.
- Fuel Efficiency: Optimized engine performance helps reduce fuel consumption and operating costs.
- Stable Power Output: High-quality alternator ensures reliable voltage and frequency output.
- Intelligent Control System: Digital control panel with real-time monitoring and engine protection functions.
- Optional ATS System: Automatic generator startup and power transfer during utility outages.
- Flexible Configuration: Available in open-type, silent-type, and containerized designs.
- Easy Maintenance: Convenient servicing and access to genuine Cummins spare parts.


Complete Pre-sales & After-sales Service





FAQ
Q1: Can the generator run continuously?
A: Yes, when configured for prime power and operated within the manufacturer's specified load and maintenance requirements. Standby-rated units are intended for emergency power applications.
Q2: Does the generator have automatic voltage regulation (AVR)?
A: Yes. An AVR system can be included to help maintain stable output voltage under changing load conditions.
Q3: Can the generator start automatically during a power failure?
A: Yes. An automatic transfer switch (ATS) can be installed to detect a mains power failure and start the generator automatically, subject to the control system configuration.
Q4: Can two 125kVA generators operate in parallel?
A: Yes. With a compatible synchronizing control system, circuit breakers, and proper electrical configuration, two or more generator sets can operate in parallel.
Q5: Does the generator come with a fuel tank?
A: A standard base fuel tank or an optional larger-capacity fuel tank can be provided, depending on the configuration.
Q6: What accessories are available?
A: Optional accessories may include an ATS, battery charger, water heater, fuel-water separator, remote monitoring system, soundproof canopy, and additional fuel tank.
Hot Tags: cummins 125kva power generator set, China cummins 125kva power generator set manufacturers, suppliers, factory, 1000kw 1250kva Cummins Genset For Data Center, 23kva Silent Cummins Diesel Generator, 500 Kw Cummins Generator, 50kva Cummins Genset, 655kw Cummins Standby Generator, cummins diesel generator