The Volvo Hospital Standby Diesel Generator Set is a reliable backup power solution designed for hospitals, medical centers, and other critical healthcare facilities. Powered by a Volvo Penta industrial diesel engine, the generator set can be equipped with a high-quality alternator, intelligent control system, automatic transfer switch, and comprehensive protection functions. When the utility power fails or becomes unstable, the system can start rapidly and provide backup power to critical loads.
| Type | Output Power | Current | Engine model | Cylinder | Bore*Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight(kg) | |
| KW | KVA | (A) | (mm) | (L) | g/kw.h | L*W*H | ||||
| JTV-68GF | 68 | 85 | 122.4 | TAD530GE | 4 | 108*130 | 4.76 | 213 | 2100*700*1450 | 1030 |
| JTV-88GF | 88 | 110 | 158.4 | TAD531GE | 4 | 108*130 | 4.76 | 214 | 2100*960*1450 | 1150 |
| JTV-112GF | 112 | 140 | 201.6 | TAD532GE | 4 | 108*130 | 4.76 | 214 | 2200*1000*1450 | 1200 |
| JTV-128GF | 128 | 160 | 230.4 | TAD731GE | 6 | 108*130 | 7.15 | 215 | 2500*1020*1450 | 1500 |
| JTV-160GF | 160 | 200 | 288 | TAD732GE | 6 | 108*130 | 7.15 | 213 | 2520*1060*1530 | 1700 |
| JTV-180GF | 180 | 225 | 324 | TAD733GE | 6 | 108*130 | 7.15 | 216 | 2550*1060*1530 | 1800 |
| JTV-200GF | 200 | 250 | 360 | TAD734GE | 6 | 108*130 | 7.15 | 204 | 2600*1100*1530 | 1950 |
| JTV-220GF | 220 | 275 | 396 | TAD734GE | 6 | 108*130 | 7.15 | 204 | 2600*1100*1530 | 1950 |
| JTV-280GF | 280 | 350 | 504 | TAD1341GE | 6 | 131*158 | 12.78 | 198 | 3100*1150*1600 | 2550 |
| JTV-300GF | 300 | 375 | 540 | TAD1342GE | 6 | 131*158 | 12.78 | 198 | 3100*1150*1600 | 2650 |
| JTV-320GF | 320 | 400 | 576 | TAD1343GE | 6 | 131*158 | 12.78 | 198 | 3100*1150*1600 | 2750 |
| JTV-350GF | 350 | 437.5 | 630 | TAD1344GE | 6 | 131*158 | 12.78 | 199 | 3100*1150*1600 | 3050 |
| JTV-400GF | 400 | 500 | 720 | TAD1345GE | 6 | 131*158 | 12.78 | 200 | 3200*1150*1880 | 3300 |
| JTV-440GF | 440 | 550 | 792 | TAD1641GE | 6 | 144*165 | 16.12 | 199 | 3200*1150*1880 | 3400 |
| JTV-480GF | 480 | 600 | 864 | TAD1642GE | 6 | 144*165 | 16.12 | 201 | 3300*1150*1880 | 3500 |
| JTV-500GF | 500 | 625 | 900 | TWD1643GE | 6 | 144*165 | 16.12 | 199 | 3350*1350*1950 | 3600 |
| JTV-550GF | 550 | 687.5 | 990 | TWD1643GE | 6 | 144*165 | 16.12 | 199 | 3400*1350*2000 | 3700 |
Using a Volvo generator set as a standby or prime power source offers several advantages:
Reliable Performance for Industrial Applications
Volvo engines are known for dependable performance and durability, making them suitable for factories that require a stable power supply.
Good Load Response
Factories often use motors, air compressors, pumps, fans, and other inductive loads. With proper sizing, the generator can better handle equipment starting and sudden load changes.
Suitable for Long-Term Operation
For factories requiring extended standby operation or continuous power, the generator can be properly configured according to the actual load, cooling requirements, and fuel capacity.



Our Advantages


Complete Pre‑sales & After‑sales Service





FAQ
Q: How Can A Volvo Penta Generator For Factory Emergency Support Factory Operations?
A: A {p} can provide standby or prime power for production equipment, utilities, lighting, pumps, compressors, and other factory loads when correctly sized. The load profile and the consequences of power interruption should guide the system design.
Q: Which Load Information Should Be Checked Before Selecting A Volvo Penta Generator For Factory Emergency?
A: Review the continuous load, peak demand, motor starting current, power factor, voltage, frequency, phase, operating hours, and expected load growth. These details help determine the required generator rating and configuration.
Q: Can A Volvo Penta Generator For Factory Emergency Support Factory Equipment With High Starting Current?
A: It can when the alternator and engine are sized for the starting demand. Motors, compressors, pumps, and other transient loads should be included in the electrical calculation rather than sizing the generator from steady-state load alone.
Q: What Duty Rating Should I Specify For A Volvo Penta Generator For Factory Emergency?
A: The choice between standby, prime, or other duty ratings depends on how often the generator will operate and the expected load profile. Buyers should provide estimated running hours and typical loading so the appropriate engine and alternator rating can be selected.
Q: What Configuration Options Are Available For A Volvo Penta Generator For Factory Emergency?
A: Depending on the model, configuration can include voltage and frequency selection, control functions, fuel-tank arrangement, enclosure type, ATS integration, remote monitoring, and other project-specific requirements. Availability should be confirmed for the selected model.
Q: What Information Helps Suppliers Quote A Volvo Penta Generator For Factory Emergency Accurately?
A: Provide the required power, voltage, frequency, phase, application, duty rating, installation location, ambient conditions, enclosure preference, control requirements, and expected operating hours. For a the specified capacity unit, a load list is especially useful for confirming the specification.
Hot Tags: volvo penta generator for factory emergency, China volvo penta generator for factory emergency manufacturers, suppliers, factory













