Key Advantages
Powered by Scania Engine
Equipped with a reliable Scania diesel engine, providing strong and stable power output for continuous operation and demanding load conditions.
Stable 50kW Power Output
Provides dependable electricity for factories, commercial facilities, construction sites and various critical equipment.
Excellent Fuel Efficiency
Advanced diesel engine technology delivers efficient fuel combustion, helping reduce fuel consumption and operating costs.
| Type | Output Power | Current | Engine model | Cyl. | Bore | Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight | |
| KW | KVA | (A) | (mm) | (mm) | (L) | g/kw.h | L*W*H | (kg) | |||
| JTS-250GF | 200 | 250 | 360 | DC09 | 5 | 127 | 145 | 40 | ≤200 | 2800*1000*1650 | 2400 |
| JTS-300GF | 240 | 300 | 432 | DC09 | 5 | 127 | 145 | 48 | ≤200 | 3000*1100*1700 | 2600 |
| JTS-330GF | 264 | 330 | 475 | DC13 | 6 | 130 | 160 | 52.8 | ≤200 | 3200*1150*1800 | 2900 |
| JTS-400GF | 320 | 400 | 576 | DC13 | 6 | 130 | 160 | 64 | ≤200 | 3400*1200*1900 | 3300 |
| JTS-450GF | 360 | 450 | 648 | DC13 | 6 | 130 | 160 | 72 | ≤200 | 3500*1250*1900 | 3500 |
| JTS-500GF | 400 | 500 | 720 | DC13 | 6 | 130 | 160 | 80 | ≤200 | 3600*1300*2000 | 3800 |
| JTS-550GF | 440 | 550 | 792 | DC16 | 8 | 130 | 154 | 88 | ≤200 | 3800*1350*2100 | 4200 |
| JTS-600GF | 480 | 600 | 864 | DC16 | 8 | 130 | 154 | 96 | ≤200 | 3900*1400*2150 | 4400 |
| JTS-660GF | 528 | 660 | 950 | DC16 | 8 | 130 | 154 | 105.6 | ≤200 | 4000*1450*2200 | 4600 |


Our Advantages
Strict Quality Control for Reliable Generator Sets
We maintain high standards for every detail throughout the manufacturing process. From structural design, welding, and component assembly to electrical connections, surface treatment, and overall workmanship, every step is carefully controlled to meet our quality requirements.


Complete Pre‑sales & After‑sales Service





FAQ
Q: What Type Of Application Is The Scania Open 50kw Diesel Generator Designed For?
A: The scania open 50kw diesel generator is intended for applications that require electrical power within its rated capacity and duty. Depending on the configuration, it can support standby, prime, commercial, industrial, construction, or project-based power requirements.
Q: Which Load Information Should Be Checked Before Selecting A Scania Open 50kw Diesel Generator?
A: Review the continuous load, peak demand, motor starting current, power factor, voltage, frequency, phase, operating hours, and expected load growth. These details help determine the required generator rating and configuration.
Q: What Duty Rating Should I Specify For A Scania Open 50kw Diesel Generator?
A: The choice between standby, prime, or other duty ratings depends on how often the generator will operate and the expected load profile. Buyers should provide estimated running hours and typical loading so the appropriate engine and alternator rating can be selected.
Q: What Configuration Options Are Available For A Scania Open 50kw Diesel Generator?
A: Depending on the model, configuration can include voltage and frequency selection, control functions, fuel-tank arrangement, enclosure type, ATS integration, remote monitoring, and other project-specific requirements. Availability should be confirmed for the selected model.
Q: What Information Helps Suppliers Quote A Scania Open 50kw Diesel Generator Accurately?
A: Provide the required power, voltage, frequency, phase, application, duty rating, installation location, ambient conditions, enclosure preference, control requirements, and expected operating hours. For a 50KW unit, a load list is especially useful for confirming the specification.
Hot Tags: scania open 50kw diesel generator, China scania open 50kw diesel generator manufacturers, suppliers, factory














