The 240kW Water-Cooled Cummins Diesel Generator is a high-performance industrial power generation solution designed for factories, manufacturing plants, commercial buildings, and other facilities requiring a reliable and stable power supply.
Powered by a genuine Cummins diesel engine and equipped with an efficient water-cooling system, this generator delivers excellent performance, stable operation, and long service life. The water-cooling system effectively regulates engine temperature during continuous operation, helping maintain reliable performance under demanding working conditions.
With a rated output of 240kW, this generator is suitable for industrial backup power applications and can also be configured for prime power use according to project requirements.
| Type | Output Power | Current | Engine model | Cylinder | Bore*Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight(kg) | |
| KW | KVA | (A) | (mm) | (L) | g/kw.h | L*W*H | ||||
| Dongfeng Cummins series. | ||||||||||
| JTC-15GF | 15 | 18.75 | 27 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| JTC-20GF | 20 | 25 | 36 | 4B3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1650*720*1200 | 700 |
| JTC-24GF | 24 | 30 | 43.2 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 710 |
| JTC-30GF | 30 | 37.5 | 54 | 4BT3.9-G2 | 4 | 102*120 | 3.9 | 208 | 1700*720*1200 | 800 |
| JTC-40GF | 40 | 50 | 72 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 920 |
| JTC-50GF | 50 | 62.5 | 90 | 4BTA3.9-G2 | 4 | 102*120 | 3.9 | 210 | 1800*750*1200 | 950 |
| JTC-64GF | 64 | 80 | 115.2 | 4BTA3.9-G11 | 4 | 102*120 | 3.9 | 210 | 1850*800*1300 | 1000 |
| JTC-80GF | 80 | 100 | 144 | 6BT5.9-G2 | 6 | 102*120 | 5.9 | 210 | 2250*800*1300 | 1250 |
| JTC-100GF | 100 | 125 | 180 | 6BTA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*800*1300 | 1300 |
| JTC-120GF | 120 | 150 | 216 | 6BTAA5.9-G2 | 6 | 102*120 | 5.9 | 207 | 2300*830*1300 | 1350 |
| JTC-150GF | 150 | 187.5 | 270 | 6CTA8.3-G2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1600 |
| JTC-180GF | 180 | 225 | 324 | 6CTAA8.3-G2 | 6 | 114*135 | 8.3 | 207 | 2400*970*1500 | 1700 |
| JTC-200GF | 200 | 250 | 360 | 6LTAA8.9-G2 | 6 | 114*145 | 8.9 | 207 | 2600*970*1500 | 2000 |
| JTC-220GF | 220 | 275 | 396 | 6LTAA8.9-G3 | 6 | 114*145 | 8.9 | 203 | 2600*970*1500 | 2000 |
| JTC-320GF | 320 | 400 | 576 | 6ZTAA13-G3 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| JTC-400GF | 400 | 500 | 720 | 6ZTAA13-G4 | 6 | 114*145 | 13 | 202 | 2900*1200*1750 | 3000 |
| JTC-400GF | 400 | 500 | 720 | QSZ13-G2 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| JTC-450GF | 450 | 562.5 | 810 | QSZ13-G3 | 6 | 130*163 | 13 | 201 | 3100*1250*1800 | 3100 |
| Chongqing Cummins series. | ||||||||||
| JTC-200GF | 200 | 250 | 360 | NT855-GA | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2600 |
| JTC-200GF | 200 | 250 | 360 | MTA11-G2 | 6 | 140*152 | 14 | 206 | 3000*1050*1750 | 2700 |
| JTC-250GF | 250 | 312.5 | 450 | NTA855-G1A | 6 | 140*152 | 14 | 207 | 3100*1050*1750 | 2900 |
| JTC-280GF | 280 | 350 | 504 | MTAA11-G3 | 6 | 125*147 | 11 | 210 | 3100*1050*1750 | 2900 |
| JTC-280GF | 280 | 350 | 504 | NTA855-G1B | 6 | 140*152 | 14 | 206 | 3100*1050*1750 | 2950 |
| JTC-300GF | 300 | 375 | 540 | NTA855-G2A | 6 | 140*152 | 14 | 206 | 3200*1050*1750 | 3000 |
| JTC-350GF | 350 | 437.5 | 630 | NTAA855-G7A | 6 | 140*152 | 14 | 205 | 3300*1250*1850 | 3200 |
| JTC-400GF | 400 | 500 | 720 | KTA19-G3A | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3700 |
| JTC-450GF | 450 | 562.5 | 810 | KTA19-G4 | 6 | 159*159 | 19 | 206 | 3300*1400*1970 | 3900 |
| JTC-500GF | 500 | 625 | 900 | KTA19-G8 | 6 | 159*159 | 19 | 206 | 3500*1500*2000 | 4200 |
| JTC-550GF | 550 | 687.5 | 990 | KTAA19-G6A | 6 | 159*159 | 19 | 206 | 3600*1500*2000 | 4800 |
| JTC-600GF | 600 | 750 | 1080 | KT38-GA | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7000 |
| JTC-650GF | 650 | 812.5 | 1170 | KTA38-G2 | 12 | 159*159 | 38 | 206 | 4300*1700*2350 | 7500 |
| JTC-700GF | 700 | 875 | 1260 | KTA38-G2B | 12 | 159*159 | 38 | 206 | 4400*1750*2350 | 8000 |
| JTC-800GF | 800 | 1000 | 1440 | KTA38-G2A | 12 | 159*159 | 38 | 206 | 4500*1750*2350 | 8200 |
| JTC-900GF | 900 | 1125 | 1620 | KTA38-G5 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 8800 |
| JTC-1000GF | 1000 | 1250 | 1800 | KTA38-G9 | 12 | 159*159 | 38 | 208 | 4500*1800*2350 | 9200 |
| JTC-1100GF | 1100 | 1375 | 1980 | KTA50-G3 | 16 | 159*159 | 50 | 205 | 5300*2080*2500 | 10000 |
| JTC-1200GF | 1200 | 1500 | 2160 | KTA50-G8 | 16 | 159*159 | 50 | 205 | 5700*2280*2500 | 10500 |
| JTC-1440GF | 1440 | 1800 | 2592 | QSK50G7 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 12500 |
| JTC-1680GF | 1680 | 2100 | 3024 | QSK60G3 | 16 | 159*190 | 60 | 205 | 5700*2280*2500 | 13000 |
| JTC-1760GF | 1760 | 2200 | 3168 | QSK60G4 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
| JTC-1840GF | 1840 | 2300 | 3312 | QSK60G13 | 16 | 159*190 | 60 | 205 | 5800*2300*2600 | 13500 |
Key Features
- Genuine Cummins Engine: Reliable engine performance, strong power output, and excellent durability.
- Water-Cooled System: Efficient engine cooling for stable operation and effective temperature control.
- High Power Output: 240kW rated power, suitable for industrial and commercial applications.
- Fuel Efficiency: Optimized combustion and efficient engine performance help reduce operating costs.
- Intelligent Control System: Digital monitoring and protection for safe and convenient operation.
- Reliable Alternator: High-quality alternator provides stable voltage and frequency output.
- Optional ATS System: Automatic power switching during utility power interruptions
- Flexible Configuration: Available in open-type, silent-type, and containerized configurations


Complete Pre-sales & After-sales Service





FAQ
Q1: Is the generator suitable for factory backup power?
A: Yes. It is suitable for providing emergency electricity to factory production lines, machinery, lighting systems, pumps, compressors, and other essential equipment during power outages. The actual suitability depends on the total load and starting requirements of the equipment.
Q2: What is the difference between a water-cooled and an air-cooled diesel generator?
A: A water-cooled generator uses coolant circulation and a radiator to remove engine heat. It is generally more suitable for medium- and large-capacity industrial generators and extended operation. An air-cooled generator uses airflow to dissipate heat and is more common in smaller power applications.
Q3: What voltage and frequency are available?
A: Common configurations include 380V, 400V, or 415V at 50Hz, and 440V or 480V at 60Hz. Other voltage configurations may be available upon request.
Q4: Is the generator three-phase or single-phase?
A: The standard industrial configuration is three-phase output, suitable for industrial machinery and commercial electrical systems. Single-phase output configurations should be confirmed according to the alternator design.
Q5: What is the difference between Prime Power and Standby Power?
A: Prime Power is designed for applications with variable loads and extended operating hours under specified conditions. Standby Power is intended for emergency use during utility power failures and is subject to specified operating limitations.
Q6: Does the generator require coolant or antifreeze?
A: Yes. The engine cooling system requires suitable engine coolant. A properly formulated coolant mixture should be used according to the engine manufacturer's recommendations and the local climate conditions.
Hot Tags: water cooled 240kw cummins diesel generator, China water cooled 240kw cummins diesel generator manufacturers, suppliers, factory, 1000kw 1250kva Cummins Genset For Data Center, 23kva Silent Cummins Diesel Generator, 500 Kw Cummins Generator, 50kva Cummins Genset, 655kw Cummins Standby Generator, cummins diesel generator