Water Cooled 240kw Cummins Diesel Generator
video
Water Cooled 240kw Cummins Diesel Generator

Water Cooled 240kw Cummins Diesel Generator

The 240kW Water-Cooled Cummins Diesel Generator is a high-performance industrial power generation solution designed for factories, manufacturing plants, commercial buildings, and other facilities requiring a reliable and stable power supply.
Send Inquiry
Description

The 240kW Water-Cooled Cummins Diesel Generator is a high-performance industrial power generation solution designed for factories, manufacturing plants, commercial buildings, and other facilities requiring a reliable and stable power supply.

Powered by a genuine Cummins diesel engine and equipped with an efficient water-cooling system, this generator delivers excellent performance, stable operation, and long service life. The water-cooling system effectively regulates engine temperature during continuous operation, helping maintain reliable performance under demanding working conditions.

With a rated output of 240kW, this generator is suitable for industrial backup power applications and can also be configured for prime power use according to project requirements.

Type Output Power Current Engine model Cylinder Bore*Stroke FuelCon. Dis. Dimension(mm ) Weight(kg)
KW KVA (A) (mm) (L) g/kw.h L*W*H
Dongfeng Cummins series.
JTC-15GF 15 18.75 27 4B3.9-G2 4 102*120 3.9 208 1650*720*1200 700
JTC-20GF 20 25 36 4B3.9-G2 4 102*120 3.9 208 1650*720*1200 700
JTC-24GF 24 30 43.2 4BT3.9-G2 4 102*120 3.9 208 1700*720*1200 710
JTC-30GF 30 37.5 54 4BT3.9-G2 4 102*120 3.9 208 1700*720*1200 800
JTC-40GF 40 50 72 4BTA3.9-G2 4 102*120 3.9 210 1800*750*1200 920
JTC-50GF 50 62.5 90 4BTA3.9-G2 4 102*120 3.9 210 1800*750*1200 950
JTC-64GF 64 80 115.2 4BTA3.9-G11 4 102*120 3.9 210 1850*800*1300 1000
JTC-80GF 80 100 144 6BT5.9-G2 6 102*120 5.9 210 2250*800*1300 1250
JTC-100GF 100 125 180 6BTA5.9-G2 6 102*120 5.9 207 2300*800*1300 1300
JTC-120GF 120 150 216 6BTAA5.9-G2 6 102*120 5.9 207 2300*830*1300 1350
JTC-150GF 150 187.5 270 6CTA8.3-G2 6 114*135 8.3 207 2400*970*1500 1600
JTC-180GF 180 225 324 6CTAA8.3-G2 6 114*135 8.3 207 2400*970*1500 1700
JTC-200GF 200 250 360 6LTAA8.9-G2 6 114*145 8.9 207 2600*970*1500 2000
JTC-220GF 220 275 396 6LTAA8.9-G3 6 114*145 8.9 203 2600*970*1500 2000
JTC-320GF 320 400 576 6ZTAA13-G3 6 114*145 13 202 2900*1200*1750 3000
JTC-400GF 400 500 720 6ZTAA13-G4 6 114*145 13 202 2900*1200*1750 3000
JTC-400GF 400 500 720 QSZ13-G2 6 130*163 13 201 3100*1250*1800 3100
JTC-450GF 450 562.5 810 QSZ13-G3 6 130*163 13 201 3100*1250*1800 3100
Chongqing Cummins series.
JTC-200GF 200 250 360 NT855-GA 6 140*152 14 206 3000*1050*1750 2600
JTC-200GF 200 250 360 MTA11-G2 6 140*152 14 206 3000*1050*1750 2700
JTC-250GF 250 312.5 450 NTA855-G1A 6 140*152 14 207 3100*1050*1750 2900
JTC-280GF 280 350 504 MTAA11-G3 6 125*147 11 210 3100*1050*1750 2900
JTC-280GF 280 350 504 NTA855-G1B 6 140*152 14 206 3100*1050*1750 2950
JTC-300GF 300 375 540 NTA855-G2A 6 140*152 14 206 3200*1050*1750 3000
JTC-350GF 350 437.5 630 NTAA855-G7A 6 140*152 14 205 3300*1250*1850 3200
JTC-400GF 400 500 720 KTA19-G3A 6 159*159 19 206 3300*1400*1970 3700
JTC-450GF 450 562.5 810 KTA19-G4 6 159*159 19 206 3300*1400*1970 3900
JTC-500GF 500 625 900 KTA19-G8 6 159*159 19 206 3500*1500*2000 4200
JTC-550GF 550 687.5 990 KTAA19-G6A 6 159*159 19 206 3600*1500*2000 4800
JTC-600GF 600 750 1080 KT38-GA 12 159*159 38 206 4300*1700*2350 7000
JTC-650GF 650 812.5 1170 KTA38-G2 12 159*159 38 206 4300*1700*2350 7500
JTC-700GF 700 875 1260 KTA38-G2B 12 159*159 38 206 4400*1750*2350 8000
JTC-800GF 800 1000 1440 KTA38-G2A 12 159*159 38 206 4500*1750*2350 8200
JTC-900GF 900 1125 1620 KTA38-G5 12 159*159 38 208 4500*1800*2350 8800
JTC-1000GF 1000 1250 1800 KTA38-G9 12 159*159 38 208 4500*1800*2350 9200
JTC-1100GF 1100 1375 1980 KTA50-G3 16 159*159 50 205 5300*2080*2500 10000
JTC-1200GF 1200 1500 2160 KTA50-G8 16 159*159 50 205 5700*2280*2500 10500
JTC-1440GF 1440 1800 2592 QSK50G7 16 159*190 60 205 5700*2280*2500 12500
JTC-1680GF 1680 2100 3024 QSK60G3 16 159*190 60 205 5700*2280*2500 13000
JTC-1760GF 1760 2200 3168 QSK60G4 16 159*190 60 205 5800*2300*2600 13500
JTC-1840GF 1840 2300 3312 QSK60G13 16 159*190 60 205 5800*2300*2600 13500

 

Key Features

 

  • Genuine Cummins Engine: Reliable engine performance, strong power output, and excellent durability.
  • Water-Cooled System: Efficient engine cooling for stable operation and effective temperature control.
  • High Power Output: 240kW rated power, suitable for industrial and commercial applications.
  • Fuel Efficiency: Optimized combustion and efficient engine performance help reduce operating costs.
  • Intelligent Control System: Digital monitoring and protection for safe and convenient operation.
  • Reliable Alternator: High-quality alternator provides stable voltage and frequency output.
  • Optional ATS System: Automatic power switching during utility power interruptions
  • Flexible Configuration: Available in open-type, silent-type, and containerized configurations

01

02

 

Complete Pre-sales & After-sales Service

 

product-1050-983

product-1050-613

product-1050-533

01

02

 

FAQ

 

Q1: Is the generator suitable for factory backup power?

A: Yes. It is suitable for providing emergency electricity to factory production lines, machinery, lighting systems, pumps, compressors, and other essential equipment during power outages. The actual suitability depends on the total load and starting requirements of the equipment.

Q2: What is the difference between a water-cooled and an air-cooled diesel generator?

A: A water-cooled generator uses coolant circulation and a radiator to remove engine heat. It is generally more suitable for medium- and large-capacity industrial generators and extended operation. An air-cooled generator uses airflow to dissipate heat and is more common in smaller power applications.

Q3: What voltage and frequency are available?

A: Common configurations include 380V, 400V, or 415V at 50Hz, and 440V or 480V at 60Hz. Other voltage configurations may be available upon request.

Q4: Is the generator three-phase or single-phase?

A: The standard industrial configuration is three-phase output, suitable for industrial machinery and commercial electrical systems. Single-phase output configurations should be confirmed according to the alternator design.

Q5: What is the difference between Prime Power and Standby Power?

A: Prime Power is designed for applications with variable loads and extended operating hours under specified conditions. Standby Power is intended for emergency use during utility power failures and is subject to specified operating limitations.

Q6: Does the generator require coolant or antifreeze?

A: Yes. The engine cooling system requires suitable engine coolant. A properly formulated coolant mixture should be used according to the engine manufacturer's recommendations and the local climate conditions.

Hot Tags: water cooled 240kw cummins diesel generator, China water cooled 240kw cummins diesel generator manufacturers, suppliers, factory, 1000kw 1250kva Cummins Genset For Data Center, 23kva Silent Cummins Diesel Generator, 500 Kw Cummins Generator, 50kva Cummins Genset, 655kw Cummins Standby Generator, cummins diesel generator

Send Inquiry

(0/10)

clearall