MTU generator sets are engineered for critical emergency power supply of data centers, mainly adopting Series 1600 & 4000 V-type industrial engines. Featuring ultra-high power density and excellent transient load acceptance performance, the units can accept 100% rated load in one single step with minor voltage & frequency deviation, perfectly matching power requirements for precise IT loads such as servers and storage devicesmtu Soluti.
| Type | Output Power | Cuurrent | Engine model | Cylinder | Bore*Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight(kg) | |
| KW | KVA | (A) | (mm) | (L) | g/kw.h | L*W*H | ||||
| JTM-220GF | 220 | 275 | 396 | 6R1600G10F | 6 | 122*150 | 10.5L | 201 | 2800*1150*1650 | 2500 |
| JTM-250GF | 250 | 312.5 | 450 | 6R1600G20F | 6 | 122*150 | 10.5L | 199 | 2800*1150*1650 | 2900 |
| JTM-300GF | 300 | 375 | 540 | 8V1600G10F | 8 | 122*150 | 14L | 191 | 2840*1600*1975 | 3250 |
| JTM-320GF | 320 | 400 | 576 | 8V1600G20F | 8 | 122*150 | 14L | 190 | 2840*1600*1975 | 3250 |
| JTM-360GF | 360 | 450 | 648 | 10V1600G10F | 10 | 122*150 | 17.5L | 191 | 3200*1600*2000 | 3800 |
| JTM-400GF | 400 | 500 | 720 | 10V1600G20F | 10 | 122*150 | 17.5L | 190 | 3320*1600*2000 | 4000 |
| JTM-480GF | 480 | 600 | 864 | 12V1600G10F | 12 | 122*150 | 21L | 195 | 3300*1660*2000 | 3900 |
| JTM-500GF | 500 | 625 | 900 | 12V1600G20F | 12 | 122*150 | 21L | 195 | 3400*1660*2000 | 4410 |
| JTM-550GF | 550 | 687.5 | 990 | 12V2000G25 | 12 | 130*150 | 23.88L | 197 | 4000*1650*2280 | 6500 |
| JTM-630GF | 630 | 787.5 | 1134 | 12V2000G65 | 12 | 130*150 | 23.88L | 202 | 4200*1650*2280 | 7000 |
| JTM-800GF | 800 | 1000 | 1440 | 16V2000G25 | 16 | 130*150 | 31.84L | 198 | 4500*2000*2300 | 7800 |
| JTM-880GF | 880 | 1100 | 1584 | 16V2000G65 | 16 | 130*150 | 31.84L | 198 | 4500*2000*2300 | 7800 |
| JTM-1000GF | 1000 | 1250 | 1800 | 18V2000G65 | 18 | 130*150 | 35.82L | 202 | 4700*2000*2380 | 9000 |
| JTM-1100GF | 1100 | 1375 | 1980 | 12V4000G21R | 12 | 165*190 | 48.7L | 199 | 6100*2100*2400 | 11500 |
| JTM-1200GF | 1200 | 1500 | 2160 | 12V4000G23R | 12 | 170*210 | 57.2L | 195 | 6150*2150*2400 | 12000 |
| JTM-1400GF | 1400 | 1750 | 2520 | 12V4000G23 | 12 | 170*210 | 57.2L | 189 | 6150*2150*2400 | 13000 |
| JTM-1500GF | 1500 | 1875 | 2700 | 12V4000G63 | 12 | 170*210 | 57.2L | 193 | 6150*2150*2400 | 14000 |
| JTM-1760GF | 1760 | 2200 | 3168 | 16V4000G23 | 16 | 170*210 | 76.3L | 192 | 6500*2600*2500 | 17000 |
| JTM-1900GF | 1900 | 2375 | 3420 | 16V4000G63 | 16 | 170*210 | 76.3L | 191 | 6550*2600*2500 | 17500 |
| JTM-2200GF | 2200 | 2750 | 3960 | 20V4000G23 | 20 | 170*210 | 95.4L | 195 | 8300*2950*2550 | 24000 |
| JTM-2400GF | 2400 | 3000 | 4320 | 20V4000G63 | 20 | 170*210 | 95.4L | 193 | 8300*2950*2550 | 24500 |
| JTM-2500GF | 2400 | 3125 | 4500 | 20V4000G63L | 20 | 170*210 | 95.4L | 192 | 8300*2950*2550 | 25000 |
Our Advantages
We carefully select raw materials and components and maintain strict quality control throughout steel fabrication, welding, assembly, electrical connections, surface treatment, and other production processes. This helps ensure excellent structural strength, stable performance, and long-term durability.


Complete Pre‑sales & After‑sales Service





FAQ
Q: What type of application is the for date center mtu engine designed for?
A: The for date center mtu engine is intended for applications that require electrical power within its rated capacity and duty. Depending on the configuration, it can support standby, prime, commercial, industrial, construction, or project-based power requirements.
Q: Which load information should be checked before selecting a for date center mtu engine?
A: Review the continuous load, peak demand, motor starting current, power factor, voltage, frequency, phase, operating hours, and expected load growth. These details help determine the required generator rating and configuration.
Q: What duty rating should I specify for a for date center mtu engine?
A: The choice between standby, prime, or other duty ratings depends on how often the generator will operate and the expected load profile. Buyers should provide estimated running hours and typical loading so the appropriate engine and alternator rating can be selected.
Q: What configuration options are available for a for date center mtu engine?
A: Depending on the model, configuration can include voltage and frequency selection, control functions, fuel-tank arrangement, enclosure type, ATS integration, remote monitoring, and other project-specific requirements. Availability should be confirmed for the selected model.
Q: What information helps suppliers quote a for date center mtu engine accurately?
A: Provide the required power, voltage, frequency, phase, application, duty rating, installation location, ambient conditions, enclosure preference, control requirements, and expected operating hours. For a the specified capacity unit, a load list is especially useful for confirming the specification.
Hot Tags: for date center mtu engine, China date center mtu engine manufacturers, suppliers, factory