It is also important to distinguish between Prime Power and Standby Power when selecting a generator. A 60 kVA generator does not necessarily provide 60 kVA under every operating condition. The correct configuration should be selected according to load characteristics, starting current, operating hours, ambient temperature, altitude, and local emission requirements.
| Type | Output Power | Current | Engine model | Cylinder | Bore*Stroke | FuelCon. | Dis. | Dimension(mm ) | Weight | |
| KW | KVA | (A) | (mm) | (L) | g/kw.h | L*W*H | (kg) | |||
| JTP-7GF | 7 | 8.75 | 12.6 | 403A-11G1 | 3 | 77*87 | 0.99 | 248 | 1200*700*1100 | 500 |
| JTP-8GF | 8 | 10 | 14.4 | 403D-11G | 3 | 77*81 | 1.13 | 252 | 1200*700*1100 | 300 |
| JTP-10GF | 10 | 12.5 | 18 | 403A-15G1 | 3 | 84*90 | 1.62 | 264 | 1250*700*1100 | 350 |
| JTP-11GF | 11 | 13.75 | 19.8 | 403D-15G | 3 | 84*90 | 1.49 | 247 | 1250*700*1100 | 350 |
| JTP-12GF | 12 | 15 | 21.6 | 403A-15G2 | 3 | 84*90 | 1.49 | 264 | 1250*700*1100 | 350 |
| JTP-16GF | 16 | 20 | 28.8 | 404A-22G1 | 4 | 84*100 | 2.2 | 237 | 1500*730*1300 | 500 |
| JTP-16GF | 16 | 20 | 28.8 | 404D-22G | 4 | 84*100 | 2.2 | 245 | 1500*730*1300 | 500 |
| JTP-24GF | 24 | 30 | 43.2 | 1103A-33G | 3 | 105*127 | 3.3 | 211 | 1770*750*1600 | 800 |
| JTP-36GF | 36 | 45 | 64.8 | 1103A-33TG1 | 3 | 105*127 | 3.3 | 211 | 2050*750*1600 | 920 |
| JTP-50GF | 50 | 62.5 | 90 | 1104A-44TG1 | 4 | 105*127 | 4.4 | 208 | 2250*750*1600 | 1100 |
| JTP-50GF | 50 | 62.5 | 90 | 1103A-33TG2 | 3 | 105*127 | 3.3 | 215 | 2200*750*1600 | 1050 |
| JTP-64GF | 64 | 80 | 115.2 | 1104A-44TG2 | 4 | 105*127 | 4.4 | 208 | 2300*750*1600 | 1150 |
| JTP-64GF | 64 | 80 | 115.2 | 1104C-44TAG1 | 4 | 100*127 | 4.4 | 205 | 2480*760*1600 | 1250 |
| JTP-80GF | 80 | 100 | 144 | 1104C-44TAG2 | 4 | 100*127 | 4.4 | 208 | 2480*760*1600 | 1250 |
| JTP-110GF | 110 | 137.5 | 198 | 1106A-70TG1 | 6 | 100*120 | 7.01 | 199 | 2480*760*1600 | 1250 |
| JTP-120GF | 120 | 150 | 216 | 1106A-70TAG2 | 6 | 105*135 | 7.01 | 208 | 2650*760*1600 | 1450 |
| JTP-140GF | 140 | 175 | 252 | 1106A-70TAG3 | 6 | 105*135 | 7.01 | 206 | 2700*900*1600 | 1700 |
| JTP-160GF | 160 | 200 | 288 | 1106A-70TAG4 | 6 | 105*135 | 7.01 | 220 | 3000*1000*1700 | 2100 |
| JTP-180GF | 180 | 225 | 324 | 1306A-E87TAG4 | 6 | 116*136 | 8.7 | 206 | 3000*1000*1700 | 2100 |
| JTP-180GF | 180 | 225 | 324 | 1506A-E88TAG2 | 6 | 112*149 | 8.8 | 200 | 3000*1000*1700 | 2100 |
| JTP-200GF | 200 | 250 | 360 | 1306A-E87TAG6 | 6 | 116*136 | 8.7 | 198 | 3100*1000*1700 | 2150 |
| JTP-200GF | 200 | 250 | 360 | 1506A-E88TAG3 | 6 | 112*149 | 8.8 | 200 | 3100*1000*1700 | 2150 |
| JTP-220GF | 220 | 275 | 396 | 1606A-E93TAG4 | 6 | 116*136 | 8.7 | 201 | 3100*1000*1700 | 2150 |
| JTP-220GF | 220 | 275 | 396 | 1506A-E88TAG4 | 6 | 112*149 | 8.8 | 198 | 3100*1000*1700 | 2150 |
| JTP-240GF | 240 | 300 | 432 | 1606A-E93TAG5 | 6 | 116*136 | 12.5 | 216 | 3100*1000*1700 | 2150 |
| JTP-240GF | 240 | 300 | 432 | 1506A-E88TAG5 | 6 | 112*149 | 8.8 | 198 | 3100*1000*1700 | 2150 |
| JTP-280GF | 280 | 350 | 504 | 2206C-E13TAG2 | 6 | 130*157 | 12.5 | 209 | 3600*1200*2000 | 3200 |
| JTP-320GF | 320 | 400 | 576 | 2206C-E13TAG3 | 6 | 130*157 | 12.5 | 206 | 3650*1200*2000 | 3300 |
| JTP-360GF | 360 | 450 | 648 | 2506C-E15TAG1 | 6 | 137*171 | 15.2 | 211 | 4000*1200*2100 | 3700 |
| JTP-400GF | 400 | 500 | 720 | 2506C-E15TAG2 | 6 | 137*171 | 15.2 | 211 | 4050*1200*2100 | 3760 |
| JTP-480GF | 480 | 600 | 864 | 2806C-E18TAG1A | 6 | 145*183 | 18.1 | 216 | 4100*1600*2200 | 4600 |
| JTP-520GF | 520 | 650 | 936 | 2806A-E18TAG2 | 6 | 145*183 | 18.1 | 202 | 4200*1600*2200 | 4800 |
| JTP-600GF | 600 | 750 | 1080 | 4006-23TAG2A | 6 | 160*190 | 22.9 | 209 | 4500*1800*2300 | 5500 |
| JTP-640GF | 640 | 800 | 1152 | 4006-23TAG3A | 6 | 160*190 | 22.9 | 209 | 4600*1800*2300 | 6000 |
| JTP-720GF | 720 | 900 | 1296 | 4008TAG1A | 8 | 160*190 | 30.5 | 206 | 4800*2100*2500 | 7700 |
| JTP-800GF | 800 | 1000 | 1440 | 4008TAG2A | 8 | 160*190 | 30.5 | 206 | 4900*2100*2500 | 8000 |
| JTP-1000GF | 1000 | 1250 | 1800 | 4012-46TWG2A | 12 | 160*190 | 45.8 | 212 | 5300*2200*2600 | 10000 |
| JTP-1100GF | 1100 | 1375 | 1980 | 4012-46TWG3A | 12 | 160*190 | 45.8 | 212 | 5300*2200*2600 | 10000 |
| JTP-1200GF | 1200 | 1500 | 2160 | 4012-46TAG2A | 12 | 160*190 | 45.8 | 212 | 5400*2200*2600 | 11000 |
| JTP-1360GF | 1360 | 1700 | 2448 | 4012-46TAG3A | 12 | 160*190 | 45.8 | 212 | 5500*2200*2600 | 12000 |
| JTP-1480GF | 1480 | 1850 | 2664 | 4016TAG1A | 16 | 160*190 | 61.1 | 205 | 5700*2800*3100 | 13500 |
| JTP-1600GF | 1600 | 2000 | 2880 | 4016TAG2A | 16 | 160*190 | 61.1 | 208 | 5800*2800*3100 | 14000 |
| JTP-1800GF | 1800 | 2250 | 3240 | 4016-61TRG3 | 16 | 160*190 | 61.1 | 205 | 5900*2800*3100 | 15700 |


Our Advantages
Strict Quality Control for Reliable Generator Sets
We always put product quality first, maintaining strict quality control throughout the entire manufacturing process-from raw material selection and production to final inspection. Our products are built with high-quality components and thick, durable steel plates, providing solid construction and reliable performance. We also use an integrated powder coating process to achieve a smooth, clean finish while improving surface durability. Every detail is carefully considered and controlled, from structural design and component assembly to finishing and workmanship. Our goal is to deliver products that are well-built, reliable, durable, and consistent in quality.


Complete Pre‑sales & After‑sales Service





FAQ
Q: What Type Of Application Is The Perkins 60kva Generator Designed For?
A: The perkins 60kva generator is intended for applications that require electrical power within its rated capacity and duty. Depending on the configuration, it can support standby, prime, commercial, industrial, construction, or project-based power requirements.
Q: What Configuration Options Are Available For A Perkins 60kva Generator?
A: Depending on the model, configuration can include voltage and frequency selection, control functions, fuel-tank arrangement, enclosure type, ATS integration, remote monitoring, and other project-specific requirements. Availability should be confirmed for the selected model.
Q: What Information Helps Suppliers Quote A Perkins 60kva Generator Accurately?
A: Provide the required power, voltage, frequency, phase, application, duty rating, installation location, ambient conditions, enclosure preference, control requirements, and expected operating hours. For a 60KVA unit, a load list is especially useful for confirming the specification.
Hot Tags: perkins 60kva generator, China perkins 60kva generator manufacturers, suppliers, factory