Perkins Diesel Generator Set is a high-performance, reliable, and economical power generation solution powered by a high-quality Perkins diesel engine. It is equipped with a reliable alternator and intelligent digital control system, providing excellent power performance, stable operation, good fuel efficiency, easy maintenance, and long service life.
Send Inquiry
Description

Key Features

1. Reliable Power Performance

Perkins diesel engines are based on proven engine technology and are designed to deliver stable power output under a wide range of operating conditions, making them suitable for applications where reliable power is important.

2. Good Fuel Efficiency

Diesel engines can provide efficient energy output under appropriate load conditions, helping users manage fuel consumption and long-term operating costs.

3. Robust Construction for Extended Operation

The generator set is built with a durable engine and base frame and can be configured for different applications, making it suitable for factories, construction projects, commercial facilities, and other demanding environments.

4. Convenient Maintenance

Perkins engines are widely used in various industries, with established maintenance practices and parts availability, making routine servicing and inspection relatively convenient.

5. Flexible Generator Configurations

The generator set can be configured with different alternator brands and specifications, controllers, cooling systems, soundproof canopies, and ATS automatic transfer switches according to project requirements.

Type Output Power Current Engine model Cylinder Bore*Stroke FuelCon. Dis. Dimension(mm ) Weight
KW KVA (A) (mm) (L) g/kw.h L*W*H (kg)
JTP-7GF 7 8.75 12.6 403A-11G1 3 77*87 0.99 248 1200*700*1100 500
JTP-8GF 8 10 14.4 403D-11G 3 77*81 1.13 252 1200*700*1100 300
JTP-10GF 10 12.5 18 403A-15G1 3 84*90 1.62 264 1250*700*1100 350
JTP-11GF 11 13.75 19.8 403D-15G 3 84*90 1.49 247 1250*700*1100 350
JTP-12GF 12 15 21.6 403A-15G2 3 84*90 1.49 264 1250*700*1100 350
JTP-16GF 16 20 28.8 404A-22G1 4 84*100 2.2 237 1500*730*1300 500
JTP-16GF 16 20 28.8 404D-22G 4 84*100 2.2 245 1500*730*1300 500
JTP-24GF 24 30 43.2 1103A-33G 3 105*127 3.3 211 1770*750*1600 800
JTP-36GF 36 45 64.8 1103A-33TG1 3 105*127 3.3 211 2050*750*1600 920
JTP-50GF 50 62.5 90 1104A-44TG1 4 105*127 4.4 208 2250*750*1600 1100
JTP-50GF 50 62.5 90 1103A-33TG2 3 105*127 3.3 215 2200*750*1600 1050
JTP-64GF 64 80 115.2 1104A-44TG2 4 105*127 4.4 208 2300*750*1600 1150
JTP-64GF 64 80 115.2 1104C-44TAG1 4 100*127 4.4 205 2480*760*1600 1250
JTP-80GF 80 100 144 1104C-44TAG2 4 100*127 4.4 208 2480*760*1600 1250
JTP-110GF 110 137.5 198 1106A-70TG1 6 100*120 7.01 199 2480*760*1600 1250
JTP-120GF 120 150 216 1106A-70TAG2 6 105*135 7.01 208 2650*760*1600 1450
JTP-140GF 140 175 252 1106A-70TAG3 6 105*135 7.01 206 2700*900*1600 1700
JTP-160GF 160 200 288 1106A-70TAG4 6 105*135 7.01 220 3000*1000*1700 2100
JTP-180GF 180 225 324 1306A-E87TAG4 6 116*136 8.7 206 3000*1000*1700 2100
JTP-180GF 180 225 324 1506A-E88TAG2 6 112*149 8.8 200 3000*1000*1700 2100
JTP-200GF 200 250 360 1306A-E87TAG6 6 116*136 8.7 198 3100*1000*1700 2150
JTP-200GF 200 250 360 1506A-E88TAG3 6 112*149 8.8 200 3100*1000*1700 2150
JTP-220GF 220 275 396 1606A-E93TAG4 6 116*136 8.7 201 3100*1000*1700 2150
JTP-220GF 220 275 396 1506A-E88TAG4 6 112*149 8.8 198 3100*1000*1700 2150
JTP-240GF 240 300 432 1606A-E93TAG5 6 116*136 12.5 216 3100*1000*1700 2150
JTP-240GF 240 300 432 1506A-E88TAG5 6 112*149 8.8 198 3100*1000*1700 2150
JTP-280GF 280 350 504 2206C-E13TAG2 6 130*157 12.5 209 3600*1200*2000 3200
JTP-320GF 320 400 576 2206C-E13TAG3 6 130*157 12.5 206 3650*1200*2000 3300
JTP-360GF 360 450 648 2506C-E15TAG1 6 137*171 15.2 211 4000*1200*2100 3700
JTP-400GF 400 500 720 2506C-E15TAG2 6 137*171 15.2 211 4050*1200*2100 3760
JTP-480GF 480 600 864 2806C-E18TAG1A 6 145*183 18.1 216 4100*1600*2200 4600
JTP-520GF 520 650 936 2806A-E18TAG2 6 145*183 18.1 202 4200*1600*2200 4800
JTP-600GF 600 750 1080 4006-23TAG2A 6 160*190 22.9 209 4500*1800*2300 5500
JTP-640GF 640 800 1152 4006-23TAG3A 6 160*190 22.9 209 4600*1800*2300 6000
JTP-720GF 720 900 1296 4008TAG1A 8 160*190 30.5 206 4800*2100*2500 7700
JTP-800GF 800 1000 1440 4008TAG2A 8 160*190 30.5 206 4900*2100*2500 8000
JTP-1000GF 1000 1250 1800 4012-46TWG2A 12 160*190 45.8 212 5300*2200*2600 10000
JTP-1100GF 1100 1375 1980 4012-46TWG3A 12 160*190 45.8 212 5300*2200*2600 10000
JTP-1200GF 1200 1500 2160 4012-46TAG2A 12 160*190 45.8 212 5400*2200*2600 11000
JTP-1360GF 1360 1700 2448 4012-46TAG3A 12 160*190 45.8 212 5500*2200*2600 12000
JTP-1480GF 1480 1850 2664 4016TAG1A 16 160*190 61.1 205 5700*2800*3100 13500
JTP-1600GF 1600 2000 2880 4016TAG2A 16 160*190 61.1 208 5800*2800*3100 14000
JTP-1800GF 1800 2250 3240 4016-61TRG3 16 160*190 61.1 205 5900*2800*3100 15700

DJI202503031533190094D

DJI202503031534070098D
DJI202503031534270100D

 

Our Advantages

Stringent Quality Control for High-Standard Manufacturing

We carefully select high-quality raw materials and implement rigorous quality management throughout every stage of production, from sheet metal fabrication, wiring harness assembly, and complete machine assembly to painting, packaging, and transportation. Through refined manufacturing processes and comprehensive quality control, we ensure consistent product quality, performance, and reliability to the highest standards.

01

02

 

Complete Pre‑sales & After‑sales Service

 

product-1050-983

product-1050-613

product-1050-533

01

02

 

FAQ

 

Q: What Type Of Application Is The Perkins Power Generator Designed For?

A: The perkins power generator is intended for applications that require electrical power within its rated capacity and duty. Depending on the configuration, it can support standby, prime, commercial, industrial, construction, or project-based power requirements.

Q: Which Load Information Should Be Checked Before Selecting A Perkins Power Generator?

A: Review the continuous load, peak demand, motor starting current, power factor, voltage, frequency, phase, operating hours, and expected load growth. These details help determine the required generator rating and configuration.

Q: Can A Perkins Power Generator Handle Motor Starting Loads?

A: It can be suitable for motor loads when the generator is correctly sized for starting current and voltage-dip requirements. Large motors, compressors, pumps, and other high-starting-current equipment should be included in the load calculation.

Q: What Duty Rating Should I Specify For A Perkins Power Generator?

A: The choice between standby, prime, or other duty ratings depends on how often the generator will operate and the expected load profile. Buyers should provide estimated running hours and typical loading so the appropriate engine and alternator rating can be selected.

Q: What Configuration Options Are Available For A Perkins Power Generator?

A: Depending on the model, configuration can include voltage and frequency selection, control functions, fuel-tank arrangement, enclosure type, ATS integration, remote monitoring, and other project-specific requirements. Availability should be confirmed for the selected model.

Q: What Information Helps Suppliers Quote A Perkins Power Generator Accurately?

A: Provide the required power, voltage, frequency, phase, application, duty rating, installation location, ambient conditions, enclosure preference, control requirements, and expected operating hours. For a the specified capacity unit, a load list is especially useful for confirming the specification.

Hot Tags: perkins power generator, China perkins power generator manufacturers, suppliers, factory

Send Inquiry

(0/10)

clearall